Gas Side Cleaner
Gas Side Cleaner HTGC-611
GAS SIDE CLEANER is sprayed undiluted on a completely dry area on to the upper most point of the system.
Product Description:
HTGC-611 is sprayed undiluted on a completely dry area on to the upper most point of the system. It contains a “clinging agent” and will run around tubes/fins and drain onto the next bank. A steady spray on the top area should be maintained until the complete unit is soaked. Very large systems may require spraying at different sections.
Product Application:
HTGC-611 is primarily intended for use in motor vessel exhaust gas heat recovery units of all designs. It can be used to clean fouled exhaust trunks. It is fully effective when used to wash down auxiliary and main boilers from the uptakes, through economizers, generating tube banks, superheaters, membrane walls, water walls and furnaces. It contains an additive to assist in the removal of vanadium.
DIRECTIONS FOR USE:
HTGC-611 is sprayed undiluted on a completely dry area on to the upper most point of the system. It contains a “clinging agent” and will run around tubes/fins and drain onto the next bank. A steady spray on the top area should be maintained until the complete unit is soaked. Very large systems may require spraying at different sections.
Please note: GAS SIDE CLEANER cannot be used after cleaning with water.
CLEANING PROCEDURE:
Check if the casing drains to the bilge are open and clear (as applicable)
Open the turbocharger casing drain to the bilge (as applicable)
Prepare spray equipment and connect gas side cleaner drum
Spray gas side cleaner starting from the highest points, ensuring that enough product is applied to allow thorough wetting of tubes/fins below and especially out of sight
Allow soaking for 30 - 60 minutes
Wash off deposits, starting from the highest point, using a fresh water jet
Keep checking the drains of the casings during wash down
Inspect system thoroughly, repeat if necessary
Product Note:
Future & Benefit:
Rapid and complete removal of soot
Neutralizes acidic components
Reduces casing drain blockages
Maintains thermal efficiency of unit
Greatly reduces fire risks
Rapid removal of carbon and Sulphur build-up